• Gc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography Machine
  • Gc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography Machine
  • Gc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography Machine
  • Gc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography Machine
  • Gc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography Machine
  • Gc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography Machine

Gc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography Machine

After-sales Service: Life Service
Warranty: 1 Year
Appliance: Medical Research
Ray Type: Gamma Ray Spectrometer
Gaspath System: Single
Detector: FID
Samples:
US$ 4600/tai 1 tai(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
GC-2010
Energy Resolution
≤7.5%
Certification
CE, ISO, IEC, GMP
Spectrometer Detector
SDD
Stationary Phase
Solid Adsorbent
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
0.2~0.5mm
Transport Package
Wooden Box
Specification
660mm *560mm*450mmm
Trademark
jinpu
Origin
Shandong Zaozhuang
HS Code
9027201100
Production Capacity
5000/Tower

Product Description

Gc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography MachineMain performance characteristics:

1. Chinese large screen LCD display, with rich and intuitive display content, and convenient parameter setting.

2. Adopting a microcomputer automatic ignition device.

3. Stable and reliable digital zeroing is adopted to avoid baseline instability caused by potentiometer zeroing.

4. It has an eighth order program heating function.

5. The intelligent rear door automatic cooling system with frequency conversion function has a fast cooling speed, achieving true near room temperature operation.

6. The column chamber adopts a unique tracking heating method; Avoiding contamination of the detector caused by rapid heating of the column chamber

7. The three gas path structure allows for the simultaneous installation of three chromatography columns, both FID and TCD detectors, and facilitates the expansion of ECD, FPD, NPD detectors, as well as the installation of external control equipment such as gas injectors and conversion furnaces.

8. Equipped with an independent capillary dedicated system, two packed column injection systems, and a high-performance capillary split/non split injector and tail blowing system, it can easily install small caliber capillary columns, large caliber capillary columns, and various packed columns.

9. This machine can be easily expanded from a single FID amplifier to a dual FID amplifier, and the parameters of the two amplifiers can be controlled separately, truly achieving one machine with multiple uses.

10. It has a power-off protection function and can automatically memorize set parameters. Equipped with anti power mutation interference function and stopwatch timing function

11. Equipped with over temperature protection function, automatically power-off and alarm when the temperature exceeds the set upper limit. If the temperature of any path exceeds the set temperature, it will automatically

Stop heating; And there are Chinese prompts for the cause of the malfunction and alarm prompts

12. Equipped with gas cut-off/leakage protection and Chinese prompt function, it can maximize the protection of TCD tungsten wire and chromatographic column from damage.
 
13.Equipped with self diagnosis function for faults, displaying Chinese fault causes and alarm prompts at any time
Temperature control technical indicators:

Temperature control range: room temperature+5 ºC -400 ºC Temperature control objects: column box, detector, thermal conductivity cell, injector

Temperature control accuracy: ± 0.1 ºC within 200 ºC; ± 0.2 ºC above 200 ºC

Program heating: Eighth order linear range rise

Rising rate: 0.1-40 ºC/minute with an increment of 0.1 ºC
Technical specifications of the detector:
detector sensitivity noise drift linear characteristic
FID Mf≤1×10 -11 g/s(benzene) ≤ 0.02mV ≤ 0.15mV/h ≥107 Platinum ignition wire, corundum ceramic nozzle
TCD S3000mV.ml/mg ≤ 0.02mV ≤ 0.15mV/h ≥105 Imported rhenium tungsten wire, constant current power supply
FPD Mp≤2×10-11g/sec(1605)
Ms≤5×10-11g/sec(thiophene)
≤ 0.02mV ≤ 0.15mV/h   Single flame design, suitable for residual analysis of sulfur and phosphorus
NPD Mf≤5×10-12g/s( azobenzene)
Mf≤5×10-12g/s(Malathion )
≤ 0.02mV ≤ 0.15mV/h   Imported rubidium beads, suitable for residual analysis of phosphorus
ECD Mf≤1×10 -13g/ml(r-666) ≤ 0.02mV ≤ 0.15mV/h ≥107 Ni63 Radiation source; Applicable for residual analysis of electronegative substances

Gc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography MachineGc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography MachineGc-2010 LCD Screen Autosampler Gas Chromatograph Gc Chromatography Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
46
Year of Establishment
2006-09-27